Remote commands
R&S
®
FSVA3000/ R&S
®
FSV3000
942
User Manual 1178.8520.02 ─ 08
AND
Combines the absolute and relative limit. The limit check fails
when both limits are violated.
OR
Combines the absolute and relative limit. The limit check fails
when one of the limits is violated.
*RST:
RELative
Manual operation:
See
[SENSe:]ESPectrum<sb>:RANGe<ri>:POINts:MINimum[:VALue]
<SweepPoint>
Defines the minimum number of sweep points for the range.
Suffix:
<sb>
.
1 to 8
<ri>
Selects the measurement range.
Parameters:
<SweepPoint>
Minimum number of sweep points per range
Range:
1 to 32001
*RST:
1
Example:
SENSe1:ESPectrum:RANGe3:POINts:MIN:VALue 400
Manual operation:
See
[SENSe:]ESPectrum<sb>:RANGe<ri>:MLCalc
<Function>
Defines the function used to calculate the limit line for the n-th power class for overlap-
ping ranges in Multi-SEM measurements. For details see
"Limit calculation for individ-
Suffix:
<sb>
.
1 to 8
Sub block in a Multi-SEM measurement
<ri>
1..n
Selects the measurement range.
Parameters:
<Function>
NONE | MAX | SUM
NONE
(reference ranges only:) the limit of the reference range is used;
Reference ranges always use the function "NONE".
SUM
sum of the two limit lines (calculated for linear powers) is used
MAX
maximum of the two limit lines is used
*RST:
SUM (reference range: NONE)
Configuring and performing measurements