SENS:MIX:FREQ:HAND 80GHz
SENS:MIX:HARM:LOW 6
SENS:MIX:LOSS:TABL:LOW 'UserTable'
SENS:MIX:HARM:HIGH 8
SENS:MIX:LOSS:HIGH 30dB
//Query the possible range
SENS:MIX:FREQ:STAR?
//Result: 47480000000 (47.48 GHz)
SENS:MIX:FREQ:STOP?
//Result: 138020000000 (138.02 GHz)
//--------------Performing the Measurement-----
//Select single sweep mode.
INIT:CONT OFF
//Initiate a basic frequency sweep and wait until the sweep has finished.
INIT;*WAI
//---------------Retrieving Results-------------
//Return the trace data (default screen configuration)
TRAC:DATA? TRACe1
12.7.1.4
Setting up probes
Modular probes can be connected to the RF input connector of the R&S
FSV/A.
For details see
Chapter 6.2.1.1, "Using probes"
[SENSe:]PROBe<pb>:ID:PARTnumber?
........................................................................ 1070
[SENSe:]PROBe<pb>:ID:SRNumber?
............................................................................1071
[SENSe:]PROBe<pb>:SETup:ATTRatio
..........................................................................1071
[SENSe:]PROBe<pb>:SETup:CMOFfset
........................................................................ 1071
[SENSe:]PROBe<pb>:SETup:DMOFfset
........................................................................ 1072
............................................................................. 1072
............................................................................1073
[SENSe:]PROBe<pb>:SETup:NMOFfset
........................................................................ 1073
........................................................................... 1073
[SENSe:]PROBe<pb>:SETup:PMOFfset
........................................................................ 1074
[SENSe:]PROBe<pb>:SETup:STATe?
............................................................................1075
.............................................................................1075
[SENSe:]PROBe<pb>:ID:PARTnumber?
Queries the R&S part number of the probe.
Suffix:
<pb>
.
1..n
Selects the connector:
3 = RF
Return values:
<PartNumber>
Setting basic measurement parameters