![Rohde & Schwarz FSV3000 User Manual Download Page 1095](http://html.mh-extra.com/html/rohde-and-schwarz/fsv3000/fsv3000_user-manual_14778431095.webp)
Remote commands
R&S
®
FSVA3000/ R&S
®
FSV3000
1095
User Manual 1178.8520.02 ─ 08
Parameters:
<Time>
Range:
0 s to 1 s
Increment: 100 ns
*RST:
100 µs
Default unit: S
Example:
PMET2:TRIG:DTIMe 0.001
[SENSe:]PMETer<p>:TRIGger:HOLDoff
<Holdoff>
This command defines the trigger holdoff for external power triggers.
Suffix:
<p>
.
Power sensor index
Parameters:
<Holdoff>
Time period that has to pass between the trigger event and the
start of the measurement, in case another trigger event occurs.
Range:
0 s to 1 s
Increment: 100 ns
*RST:
0 s
Default unit: S
Example:
PMET2:TRIG:HOLD 0.1
Sets the holdoff time of the trigger to 100 ms
Manual operation:
See
[SENSe:]PMETer<p>:TRIGger:HYSTeresis
<Hysteresis>
This command defines the trigger hysteresis for external power triggers.
The hysteresis in dB is the value the input signal must stay below the IF power trigger
level to allow a trigger to start the measurement.
Suffix:
<p>
.
Power sensor index
Parameters:
<Hysteresis>
Range:
3 dB to 50 dB
Increment: 1 dB
*RST:
0 dB
Default unit: DB
Example:
PMET2:TRIG:HYST 10
Sets the hysteresis of the trigger to 10 dB.
Manual operation:
See
[SENSe:]PMETer<p>:TRIGger:LEVel
<Level>
This command defines the trigger level for external power triggers.
Setting basic measurement parameters