CHAPTER 29:Indicator PWM
S6J3200 Series Hardware Manual Document Number: 002-04852 Rev. *G
1097
3.5.2.
Interrupt Factors and Timing Chart (PWM Output: Normal Polarity)
Figure 3-5: PWM Timer Interrupt Factors and Timing Chart
CTEN
Load
Count clock
Count value
PWM output
waveform
Interrupt
0x0003
0x0001
0x0002
0x0000
0x0003
0x0002
Start-up
edge
Duty match
DTIR
Underfolw
UDIR
0xXXXX
DOP
STRG
Figure 1-1 shows the interrupt factors and a timing chart for when the setting value is 0x3 and the duty
value is 0x1.
3.5.3.
Return from PSS Mode
An interrupt of indicator PWM can be applied to a trigger of returning from PSS mode. Then the bus clock
CLK_SYSC0P should be supplied during the PSS mode.