CHAPTER 15:12-/10-/8-bit Analog to Digital Converter
S6J3200 Series Hardware Manual Document Number: 002-04852 Rev. *G
273
Table 3-2 Description About Multiple Conversion after Interrupted (ADC12Bn_CTRL.FSMD = "1")
Settings
Description of Trigger Status and Conversion Counter after Interrupted
ADC12Bn_MCCTRL0 to
3.
ICIRQY
ADC12Bn_CHCTRL0 to
63.
RSMRST[1:0]
"0" (can be interrupted
between single
conversion)
"00" (Stop)
Imposes the trigger status flag clearing.
Keeps current value of the conversion counter. It is cleared by next conversion
request.
"01" (Resume)
Keeps the trigger status flag set.
The conversion counter is cleared immediately. It means that the accumulated
conversion result before the interrupt is not really usable because it is not
known how many conversions are done.
"10" (Restart)
The trigger status flag stays set only if the channel is first channel in the group,
otherwise the trigger status of the channel is cleared and instead the trigger
status flag of the first channel in the subgroup is set.
The conversion counter is cleared immediately. It means that the accumulated
conversion result before the interrupt is not really usable because it is not
known how many conversions are done.
"1" (cannot be interrupted
between single
conversion)
"00" (Stop)
Imposes the trigger status flag clearing.
Keeps current value of the conversion counter. It is cleared by next conversion
request.
"01" (Resume)
Keeps the trigger status flag set and current value of the conversion counter.
"10" (Restart)
The trigger status flag stays set only if the channel is first channel in the group,
otherwise the trigger status of the channel is cleared and instead the trigger
status flag of the first channel in the subgroup is set.
The conversion counter is cleared immediately. It means that the accumulated
conversion result before the interrupt is not really usable because it is not
known how many conversions are done.
−
In the case that range comparison is enabled for a multiple conversion channel, every conversion
result is passed to the range comparator.
−
For notes of data protection about multiple conversion, refer to section "Logical channel data
protection function" in chapter "3. Operation of A/D ".
Summary of Contents for S6J3200 Series
Page 1041: ...CHAPTER 28 LCD Controller 1040 S6J3200 Series Hardware Manual Document Number 002 04852 Rev G...
Page 1044: ...CHAPTER 28 LCD Controller S6J3200 Series Hardware Manual Document Number 002 04852 Rev G 1043...
Page 1047: ...CHAPTER 28 LCD Controller 1046 S6J3200 Series Hardware Manual Document Number 002 04852 Rev G...
Page 1050: ...CHAPTER 28 LCD Controller S6J3200 Series Hardware Manual Document Number 002 04852 Rev G 1049...
Page 1084: ...CHAPTER 28 LCD Controller S6J3200 Series Hardware Manual Document Number 002 04852 Rev G 1083...
Page 1086: ...CHAPTER 28 LCD Controller S6J3200 Series Hardware Manual Document Number 002 04852 Rev G 1085...
Page 1088: ...CHAPTER 28 LCD Controller S6J3200 Series Hardware Manual Document Number 002 04852 Rev G 1087...