CHAPTER 27:HyperBus Interface
1012
S6J3200 Series Hardware Manual Document Number: 002-04852 Rev. *G
3.3.
C/A Coder
The HYPERBUSI module outputs 6 bytes of command/address information to define the transaction. The
C/A Coder builds a command/address information by the request from AXI bus and the register settings.
Table 3-1 C/A Format of HYPERBUSI
C/A Bit
Name
Assignment
47
R/W#
0: Write, 1: Read
46
Target
CRT in HYPERBUSI_MCRn
45
Burst Type
0: WRAP, 1: INCR
44
RFU
0
43 - 16
Page Address
Address [31:4]
15
RFU
0
14 - 13
RFU
3
12 - 3
RFU
0
2 - 0
Column Address
Address [3:1]