Model 013-02-0095-002 

Elemec3

 System Controller 

Confidentiality Notice 

This manual is provided solely as an operational, installation, and maintenance guide and contains 
sensitive business and technical information that is confidential and proprietary to GAI-Tronics.  
GAI-Tronics retains all intellectual property and other rights in or to the information contained herein, 
and such information may only be used in connection with the operation of your GAI-Tronics product or 
system.  This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any 
third party. 

General Information 

The Model 013-02-0095-002 

Elemec3

 System Controller is the central component of an 

Elemec3

 central 

amplifier system, processing all operations through its highly configurable system software.  It is 
designed to be installed in a standard (19-inch) 

Elemec3

 system control cabinet. 

The 

Elemec3

 System Controller provides continuous monitoring functions for up to 16 Microphone 

Access Panels and sends/receives data from the Elemec

plus

 Power Amplifiers, to provide complete high 

integrity system monitoring, from microphone panel to loudspeaker.  The integral software audio players 
and the 

Elemec3

 System Controller to amplifier audio paths are also monitored. 

Figure 1.  

Elemec3

 System Controller 

Summary of Contents for Elemec3 013-02-0095-002

Page 1: ...ation of your GAI Tronics product or system This manual may not be disclosed in any form in whole or in part directly or indirectly to any third party General Information The Model 013 02 0095 002 Ele...

Page 2: ...ed relay outputs and 256 input contact points are available through the LAN interface on the rear of the Elemec3 System Controller Duplicate Elemec3 System Controller can be used for additional redund...

Page 3: ...required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to...

Page 4: ...4 of 11 e standard ioms current release 42004 instr manuals 42004 480b doc 05 14 Rear Panel Connections Refer to Figure 3 System connections are made to the rear of the Elemec3 System Controller US C...

Page 5: ...ntroller Internal Components Component Description Digital PCBA Central processing unit and digital communications Analog PCBA Provides speech recording and play back to eliminate feedback Telephone I...

Page 6: ...rack It requires 1U 1 75 inches of height Duplicate System In a duplicated or redundant system two Elemec3 System Controllers designated as A and B are located in system racks at different location In...

Page 7: ...EDs operate in accordance with the following table Table 2 Front Panel LED Indications LED Indication PA IN USE Green Indicates the PA system is in use Off Not in use SYSTEM STATUS Green Normal operat...

Page 8: ...fications via the LAN connection on the rear panel PABX connection The interface to the telephone system is made via the PABX connector on the rear panel API 1 API 4 Access panel interface connections...

Page 9: ...terface cards T500 mA F8 Input Output Cards T1 6 A F1 Auxiliary Power Output T2 5 A Power to access panels is fused to 100 mA on Access Panel Interface cards Access Panel Interfaces Access panels per...

Page 10: ...eed 57 6 kbps A B Interlinks Audio Input Operating level 2 2 Vpp maximum at 1 kHz Input impedance 60 k ohms at 1 kHz 3 dB bandwidth 200 Hz 20 kHz input to zone output Data Link Type RS 485 fully duple...

Page 11: ...nhibit Status LEDs Unit Power PA In Use System Status Status Monitor Elemec3 Portal Ports Ethernet Port RJ45 Connector USB Device Port Front Type A USB Device Port Rear Type A O C Voltage 5 1 V dc nom...

Page 12: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...