JABLOTRON
ALARMS
a.s.
Pod
Skalkou
4567/33
46601
Jablonec
n.
Nisou
Czech
Republic
www
.jablotron.com
||
|
JA-16J One-way four-button keyfob
JA-16J One-way four button keyfob
1 / 2
MMJ21101
The JA-16J is a component of the
JA-10
system. It uses one way
communication. It is designed to remotely control a security system,
various appliances (using PG programmable outputs PG) or to
trigger panic alarms. The remote is equipped with optical and
acoustic indication. It checks its battery status and indicates when
the battery is nearly discharged.
Figure:
1 – LED indication;
A, B, C, D – buttons, see their functions according to table 1.
Enrolling the remote control to a control
panel
There must be a JA-111R radio module installed in the control
panel for the ability to work with a control panel. The remote can be
enrolled to an arbitrary number of JA-10 systems and one pair of
buttons can control multiple sections in the system (common
control). It occupies one position in the system.
1. Control panel has to be in service mode.
2. Basic procedure:
a. Go to the
N-Link
software, select the required position
in the
Devices
tab and launch
enrollment
mode.
b. For the transmission of an enrollment signal press and hold
buttons (A+B) simultaneously for at least 3 s (within this time
the red LED flashes rapidly).
c. After 3 s the enrollment signal is sent and confirmed by one
long LED flash. Release both buttons and close enrollment
mode.
To set the keyfob to comply with security
grade 2 or other requirements use the
N-Link SW, open Parameters tab and select
corresponding option from “System
Profiles”(See the JA-10 control panel
installation manual).
Notes:
−
Enrolling the remote control to the system is possible by
entering the production code via N-Link software.
The production code is on the sticker with a bar code glued
onto the battery holder inside the remote. All digits in the
production code are required (1400-00-0000-0001).
−
If you want to remove the remote control from the system
(for instance when someone has lost it), erase it from the
particular address of the control panel.
Setting the properties
Perform settings using
N-Link
software –
Devices
tab. Click
on the JA-16J´s
Internal settings
. Then a window appears
automatically where you can set the following parameters:
Functions of the buttons:
set a particular function for the pair
of buttons A-B or C-D (setting / unsetting typically, ON / OFF
switching of some appliance, etc.) or a function for each single
button A, B, C, D (gate opening, garage door opening, etc.) and
a double press of the A+B or C+D buttons, which can trigger silent
panic. For an option overview see table 1.
Reaction for single buttons
/
/
/
(A/B/C/D)
Reaction for pressing
simultaneously
+
/
+
(A+B/C+D)
−
None (button not used)
−
Change PG state
−
Silent panic *)
−
Audible panic *)
−
Health troubles
−
Silent panic
Reaction for pair of buttons
-
/
-
(A-B/C-D)
−
Unset / Set
−
Unset / Partially set
−
Unset / Partially set / Set
−
Unset/Set with confirmation
−
Unset/Set partially with confirmation
−
Unset/Set partially/Set with confirmation
−
PG OFF / PG ON
Table: 1. Button function options overview
For each function selected for a remote control button it is
necessary to select the appropriate PG or sections to be controlled
or from which reports should be sent (panic, etc.). For the common
control of multiple sections it
is not recommended
to operate
a common section, but to select the desired section in the remote
control internal settings.
Notes:
*) The reactions of the buttons which are not supported when
the system is configured to comply with security grade 2.
−
The option “
Do not set with active zone“,
doesn´t allow the
system to be set using a remote control (keyfob) when any
zone with an
Instant
reaction is active. To set the system all
zones / detectors have to be in standby
Pressing both triggers a silent panic
: According to the settings
control panel reacts to double pressing of those buttons by
triggering silent panic alarm from the section where the keyfob has
been enrolled. When the keyfob is locked down its necessary to
perfrom doubles press 2x per 1 sec. Confirmed by flash of red LED
on the keyfob.
Assign to user:
Takes over user’s access privileges for the
sections and time limited access according to the specific user.
Locking the keyfob
The remote control buttons can be locked (blocked) against
accidental pressing. Locking is disabled by default, pressing any
button triggers its function immediately. If the buttons are locked,
a control panel command is sent when a button is pressed 2x
quickly (2x per 1 s) it is also valid for the panic function.
The
lock can be activated
by pressing and holding the pair
of buttons (A+B) at the same time. After pressing both buttons the
red LED (1) flashes 1x and subsequently after 3 s the red LED
starts flashing quickly, during LED flashing release button B and
then press it again. Activation of the lock function is performed and
confirmed by double flashes of the red LED and a double beep.
After this confirmation release all buttons.
The
lock is deactivated
by repeating the procedure above.
Deactivation of locking is confirmed by one flash of the red LED
and one beep.
Caution: When a reaction for pressing buttons (A+B)
simultaneously is set (for example a panic alarm or garage
door control), it is necessary to mind that the action
is performed first.
Acoustic indication
Acoustic indication can be completely disabled. The default
is enabled. When any button is pressed it is followed by a short
acoustic signal according to the table 2.
The
acoustic indication
can be disabled by simultaneous pressing
and holding the pair of buttons (A+B) until the red LED (1) starts
flashing briefly for the second time, usually in 6 s. When the red LED (1)
flashes a second time release the button (B) and press it again. The
acoustic indication is then disabled and confirmed by flashes of the red
LED and a one beep. After this confirmation release all buttons.
The
acoustic indication
can be enabled by repeating
the procedure above. Activation is confirmed by a double flash
of the red LED and a double beep.
Caution: When a reaction for pressing buttons (A+B) simulta-
neously is set (for example a panic alarm or garage door
control), it is necessary to mind that the action is performed
first.