The E4KP EntryCheck™ is a fully self-contained proximity access control reader.  It is keypad programmable and 
does not require software or a PC connection.

INSTALLATION/PROGRAMMING INSTRUCTIONS

E4KP ENTRYCHECK

P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd     Rev C      10-09     Page 1

Features

HID compatible Proximity Reader
Up to 3" read range with ProxCard II
Weather resistant reader enclosure
Memory capacity stores up to 650 user cards
Cost-effective solution for access control and 
personnel management
Access mode selectable

1. Proximity card only
2. Proximity card + PIN

Master code for programming functions
Main password function

Security password function
Forced entry alarm
Door prop alarm
Duress output
User card can be registered/deleted in single

or batch mode (with consecutive numbers)

Reader Lockout activated when the wrong card is

presented more than five times

Lock and alarm output relays programmable

1-99 seconds or on-off latching

Separate remotely located relay module for

for higher security

Optional Cards & Key Fobs

Part# 

HID1326-10 

– (10) Prox Cards, HID ProxCard II

Part# 

HID1346-10 

– (10) Prox Key Fobs, HID ProxKey II

HID ProxCard®  II & ProxKey®  II are registered trademarks of HID Corporation

Summary of Contents for E4KP ENTRYCHECK

Page 1: ... user cards Cost effective solution for access control and personnel management Access mode selectable 1 Proximity card only 2 Proximity card PIN Master code for programming functions Main password function Security password function Forced entry alarm Door prop alarm Duress output User card can be registered deleted in single or batch mode with consecutive numbers Reader Lockout activated when th...

Page 2: ...d Red When the Strike Relay is active the LED will be Solid Green To Open the Door using an HID card or fob in Mode 1 Present a valid card or fob within a couple of inches of the reader Solid Green LED To Open the Door using an HID card or fob in Mode 2 Present a valid card or fob within a couple of inches of the reader Slow Flashing Red LED Enter the 4 digit PIN Solid Green LED QUICKSTART PROGRAM...

Page 3: ...ally be found on one side of the HID Card or Fob See Pg 2 If a card ever needs to be deleted you will need the card or the card number Adding a Single Card OR Card Number Enter Programming Mode Alternating Red Green LED Press 4 Fast alternating Red Green LED Present Card OR Enter the Card Number 0 65535 Flashing Red LED Key in a 4 digit PIN If you do not want to enter a PIN just Press Fast alterna...

Page 4: ...isable Press 810 Alternating Red Green LED Press to exit Programming Solid Red LED NOTE DIP SWITCH 1 on the E5RM control module must be ON Shunt cannot be used if Anti Duress is enabled Set Anti Duress Relay Time Default Anti Duress Disabled With the Anti Duress Relay Enabled the Auxiliary K3 Relay will activate when the Door Open Password See Factory Defaults OR a User s PIN Entry Mode 2 ONLY is ...

Page 5: ...n condensing Change Default Passwords Enter Programming Mode Alternating Red Green LED To change System Setup Password Default 111111 Press New 6 digit Password Alternating Red Green LED To change Door Open Password Default 1234 Press New 4 digit Password Alternating Red Green LED To change Patrol Password Default 1234567 Press New 7 digit Password Alternating Red Green LED Press to exit Programmi...

Page 6: ...ti Duress feature and or Patrol Function 4 J1 J2 J3 Connectors are included with the E5RM Power Supply Exit Button Door Switch are sold separately P INSTALLATION INST Access Controls INST E4KP INST E4KP vsd Rev C 10 09 Page 6 5 For DC voltage electric strikes and electric bolt locks install a Metal Oxide Varistor MOV as close to the coil as possible to prevent kickback voltage from damaging the re...

Reviews: