background image

(+) (-)

12VR

MODULE

POWER

SUPPLY

24VDC

(+) (-)

12V

24V

600 SERIES

POWER SUPPLY 

WITH 

12VR MODULE

(+)

+12V

GND

CLOCK

DATA

RED

BLK
BRN

ORG

RED

BLK
BRN

ORG

J3

RED

BLK
BRN

ORG

E4KP

KEYPAD

YEL

E5RM 

CONTROLLER RELAY MODULE

NOT 

USED

RED

BLK
BRN

ORG

YEL
GRN

BLU

YEL

GRN

BLU
YEL

GRN

BLU

+

-

12 VDC

LOCK

OUTPUT

ALARM

OUTPUT

AUX. OUTPUT

(DIP SW SELECTABLE)

C

NC

NO

C

NC
NO

C

NC

NO

Request -to-Exit

Door Status

J2

J1

RED

BLK
BRN

ORG

YEL
GRN

BLU

YEL

GRN

BLU
YEL

GRN

BLU

(+)

REX BUTTON

N.O. DRY CONTACT

(OPTIONAL)

DOOR STATUS 

SWITCH

N.O. OR N.C.

(OPTIONAL)

TYPICAL WIRING DIAGRAM

Installation Notes:

1.  Max distance between the E4KP Keypad & E5RM is 300ft.
2.  Alarm Output Relay will be used for Door Prop or Forced Door Alarm.
3.  Auxiliary Output Relay will be used for Shunt/Anti-Duress feature and/or Patrol Function.
4.  J1, J2, & J3 Connectors are included with the E5RM.  Power Supply, Exit Button, & Door Switch are sold separately.

P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd     Rev C      10-09     Page 6

5.  For DC voltage electric strikes and electric bolt locks, install a Metal Oxide Varistor (MOV) as close to the coil as possible to 
prevent kickback voltage from damaging the relay module.  Consult with the Lock Manufacturer to see if a voltage suppression 
device is necessary. 

300 ft MAX

FAIL

SECURE

LOCK

+

-

MOV

FAIL 

SAFE 

LOCK

+

-

MOV

Keypad 

Power

12VDC ONLY

12V or 24VDC

(-)

Lock

Power

(-)

Keypad 

Power

Lock

Power

(+)

OR

USE WITH

24vdc LOCKS

*

 KEYPAD POWER IS 12V DC ONLY.

CONNECTING A HIGHER VOLTAGE OR AC

WILL DAMAGE THE  UNIT AND VOID THE 

WARRANTY   

*

(+)

(-)

(-)

POWER

SUPPLY

12VDC

(+) (-)

12V

Keypad 

Power

Lock

Power

600 SERIES

POWER SUPPLY 

USE WITH

12vdc LOCKS

NOTE:

Dual voltage power supplies should be 

switched to 12VDC prior to hook-up   

Summary of Contents for E4KP ENTRYCHECK

Page 1: ... user cards Cost effective solution for access control and personnel management Access mode selectable 1 Proximity card only 2 Proximity card PIN Master code for programming functions Main password function Security password function Forced entry alarm Door prop alarm Duress output User card can be registered deleted in single or batch mode with consecutive numbers Reader Lockout activated when th...

Page 2: ...d Red When the Strike Relay is active the LED will be Solid Green To Open the Door using an HID card or fob in Mode 1 Present a valid card or fob within a couple of inches of the reader Solid Green LED To Open the Door using an HID card or fob in Mode 2 Present a valid card or fob within a couple of inches of the reader Slow Flashing Red LED Enter the 4 digit PIN Solid Green LED QUICKSTART PROGRAM...

Page 3: ...ally be found on one side of the HID Card or Fob See Pg 2 If a card ever needs to be deleted you will need the card or the card number Adding a Single Card OR Card Number Enter Programming Mode Alternating Red Green LED Press 4 Fast alternating Red Green LED Present Card OR Enter the Card Number 0 65535 Flashing Red LED Key in a 4 digit PIN If you do not want to enter a PIN just Press Fast alterna...

Page 4: ...isable Press 810 Alternating Red Green LED Press to exit Programming Solid Red LED NOTE DIP SWITCH 1 on the E5RM control module must be ON Shunt cannot be used if Anti Duress is enabled Set Anti Duress Relay Time Default Anti Duress Disabled With the Anti Duress Relay Enabled the Auxiliary K3 Relay will activate when the Door Open Password See Factory Defaults OR a User s PIN Entry Mode 2 ONLY is ...

Page 5: ...n condensing Change Default Passwords Enter Programming Mode Alternating Red Green LED To change System Setup Password Default 111111 Press New 6 digit Password Alternating Red Green LED To change Door Open Password Default 1234 Press New 4 digit Password Alternating Red Green LED To change Patrol Password Default 1234567 Press New 7 digit Password Alternating Red Green LED Press to exit Programmi...

Page 6: ...ti Duress feature and or Patrol Function 4 J1 J2 J3 Connectors are included with the E5RM Power Supply Exit Button Door Switch are sold separately P INSTALLATION INST Access Controls INST E4KP INST E4KP vsd Rev C 10 09 Page 6 5 For DC voltage electric strikes and electric bolt locks install a Metal Oxide Varistor MOV as close to the coil as possible to prevent kickback voltage from damaging the re...

Reviews: