background image

PROGRAMMING OPTIONS

Set Alarm Relay Time (Default = 5 sec)

Enter Programming Mode  

{Alternating Red & Green LED}

Press 2 + [00-99 seconds] + #  

{Alternating Red & Green LED}

Press # to exit Programming 

{Solid Red LED}

NOTE:

The Alarm Relay is used for Forced Door & Door Prop alarms. 00 = Non-stop alarm – Reset by using a valid card.

Enable Forced Door Alarm Relay (Default =  Force Door Disabled)

Enter Programming Mode  

{Alternating Red & Green LED}

To enable

, Press 841 + #  

{Alternating Red & Green LED}

To disable

, Press 840 + #  

{Alternating Red & Green LED}

Press # to exit Programming  

{Solid Red LED}

NOTE

:  A Door Position Sensor must be installed. 

Enable & Set Door Prop Time (Default =  Door Prop Disabled)

Enter Programming Mode  

{Alternating Red & Green LED}

To enable

, Press  881 + #  

{Alternating Red & Green LED}

           Press 3 + [01-99 seconds] + #  (sets Door Prop Time; Default = 00) 

{Alternating Red & Green LED}

To disable

, Press 880 + #  

{Alternating Red & Green LED}

           Press 300 + #  

{Alternating Red & Green LED}

Press # to exit Programming  

{Solid Red LED}

NOTE

:  A Door Position Sensor must be installed.   Relay will remain activated until the door closes OR the Alarm Relay 

time expires, whichever occurs first.

Set Shunt Relay Time (Default =  Shunt Disabled)

With the Shunt Relay Enabled, the Auxiliary (K3) Relay will activate simultaneously with the Strike Relay:  

Enter Programming Mode  

{Alternating Red & Green LED}

To enable

, Press 812 + # 

{Alternating Red & Green LED}

           Press 0 + [01-99 seconds] + #  (sets Shunt Relay Time; Default = 01) 

{Alternating Red & Green LED}

To disable

, Press 810 + # 

{Alternating Red & Green LED}

Press # to exit Programming 

{Solid Red LED}

NOTE

:  DIP SWITCH 1 on the E5RM control module, must be ON.  Shunt cannot be used if Anti-Duress is enabled.

Set Anti-Duress Relay Time (Default =  Anti-Duress Disabled)

With the Anti-Duress Relay Enabled, the Auxiliary (K3) Relay will activate when the Door Open Password (See Factory 
Defaults) OR a User’s PIN (

Entry Mode 2 ONLY

), is entered, followed by a ‘9’:    

Enter Programming Mode 

{Alternating Red & Green LED}

To enable

, Press 811 + # 

{Alternating Red & Green LED}

           Press 0 + [01-99 seconds] + #  (sets Duress Relay Time; Default = 01) 

{Alternating Red & Green LED}

To disable

, Press 810 + # 

{Alternating Red & Green LED}

Press # to exit Programming 

{Solid Red LED}

NOTE

:  DIP SWITCH 1 on the E5RM control module, must be ON.  Anti-Duress cannot be used if Shunt is enabled.

Enable Reader Lockout (Default = Disabled)

Enabling this function will do the following:
1.  If an invalid card or card number is used (5) times in a row, this option will “Lockout” the keypad for approx. 1 minute.
2.  In 

Entry Mode 2

, if an invalid PIN number is entered over (5) times, the card will automatically be deleted.

Enter Programming Mode  

{Alternating Red & Green LED}

To enable

, Press 851 + #  

{Alternating Red & Green LED}

To disable

, Press 850 + #  

{Alternating Red & Green LED}

Press # to exit Programming  

{Solid Red LED}

Set Door Status Sensor Configuration (Default = Normally Open)

Enter Programming Mode  

{Alternating Red & Green LED}

For Normally Closed

, Press 861 + # 

{Alternating Red & Green LED}

For Normally Open

, Press 860 + #  

{Alternating Red & Green LED}

Press # to exit Programming  

{Solid Red LED}

P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd     Rev C      10-09     Page 4

Summary of Contents for E4KP ENTRYCHECK

Page 1: ... user cards Cost effective solution for access control and personnel management Access mode selectable 1 Proximity card only 2 Proximity card PIN Master code for programming functions Main password function Security password function Forced entry alarm Door prop alarm Duress output User card can be registered deleted in single or batch mode with consecutive numbers Reader Lockout activated when th...

Page 2: ...d Red When the Strike Relay is active the LED will be Solid Green To Open the Door using an HID card or fob in Mode 1 Present a valid card or fob within a couple of inches of the reader Solid Green LED To Open the Door using an HID card or fob in Mode 2 Present a valid card or fob within a couple of inches of the reader Slow Flashing Red LED Enter the 4 digit PIN Solid Green LED QUICKSTART PROGRAM...

Page 3: ...ally be found on one side of the HID Card or Fob See Pg 2 If a card ever needs to be deleted you will need the card or the card number Adding a Single Card OR Card Number Enter Programming Mode Alternating Red Green LED Press 4 Fast alternating Red Green LED Present Card OR Enter the Card Number 0 65535 Flashing Red LED Key in a 4 digit PIN If you do not want to enter a PIN just Press Fast alterna...

Page 4: ...isable Press 810 Alternating Red Green LED Press to exit Programming Solid Red LED NOTE DIP SWITCH 1 on the E5RM control module must be ON Shunt cannot be used if Anti Duress is enabled Set Anti Duress Relay Time Default Anti Duress Disabled With the Anti Duress Relay Enabled the Auxiliary K3 Relay will activate when the Door Open Password See Factory Defaults OR a User s PIN Entry Mode 2 ONLY is ...

Page 5: ...n condensing Change Default Passwords Enter Programming Mode Alternating Red Green LED To change System Setup Password Default 111111 Press New 6 digit Password Alternating Red Green LED To change Door Open Password Default 1234 Press New 4 digit Password Alternating Red Green LED To change Patrol Password Default 1234567 Press New 7 digit Password Alternating Red Green LED Press to exit Programmi...

Page 6: ...ti Duress feature and or Patrol Function 4 J1 J2 J3 Connectors are included with the E5RM Power Supply Exit Button Door Switch are sold separately P INSTALLATION INST Access Controls INST E4KP INST E4KP vsd Rev C 10 09 Page 6 5 For DC voltage electric strikes and electric bolt locks install a Metal Oxide Varistor MOV as close to the coil as possible to prevent kickback voltage from damaging the re...

Reviews: