background image

 

 
 

DMX-LED-DIMMER X9 HR 

 

9x 16 BIT PWM per 10A 

 

 
 

User Manual 

 
 
 
 

 

Summary of Contents for DMX-LED-DIMMER X9 HR

Page 1: ...DMX LED DIMMER X9 HR 9x 16 BIT PWM per 10A User Manual ...

Page 2: ...DMX PWM PWM DMX Energy Saving Design By modern switch mode technology less heat will be generated and thus the energy consumption will be reduced Technical Data Power supply 7 24V DC 100mA without load LED voltage 7 24V DC no AC voltage DMX 9 channels with 8Bit controlling and LookUp table 18 channels with 16Bit controlling optional master dimmer channels DMX Fail Hold Off On Output 9 PWM signal w...

Page 3: ...DMX LED Dimmer X9 HR 3 Dimensions 99 x 82 mm ...

Page 4: ... LED Stripe 12V POWER 12V GND V GND OUT1 GND OUT2 GND OUT3 GND OUT4 GND OUT5 GND OUT6 RGB LED Stripe 12V RGB LED Stripe 12V V DMX DMX GND ADDRESS GND GND GND OUT7 OUT8 OUT9 DMX IN DMX OUT CFG Must be connected direct from the power supply Depends on the current for the LED Stripes ...

Page 5: ...12V POWER 12V GND V GND OUT1 GND OUT2 GND OUT3 GND OUT4 GND OUT5 GND OUT6 RGB LED Stripe 24V RGB LED Stripe 12V V DMX DMX GND ADDRESS GND GND GND OUT7 OUT8 OUT9 DMX IN DMX OUT POWER 12V POWER 24V POWER 12V CFG Must be connected direct from the power supply Depends on the current for the LED Stripes ...

Page 6: ... X9HR RGB LED Stripe 12V POWER 12V GND V GND OUT1 GND OUT2 GND OUT3 GND OUT4 GND OUT5 GND OUT6 LED Stripe WEIß 12V LED Stripe WEIß 12V V DMX DMX GND ADDRESS GND GND GND OUT7 OUT8 OUT9 DMX IN DMX OUT CFG Must be connected direct from the power supply Depends on the current for the LED Stripes ...

Page 7: ...es permanent In this case the device is working Furthermore the LED shows the events In this case the LED lights in short pitches and than turns into the off mode for a longer period The number of flashing impulses corresponds with the event number Error Status Error Description 1 No DMX There is no DMX Signal reaching the dimmer 2 Address error Check if a valid DMX starting address is adjusted at...

Page 8: ...he configuration switch 4 Switch 4 OFF Controlling the outputs via one DMX channel In this operation mode each output has a LookUp table This displays the outputs 16Bit resolution for the available 256 values of the DMX channels The LookUp tables are linear programmable ex ante and freely programmable Switch 4 ON Controlling the outputs via two DMX channels Each output has a 16Bit resolution For a...

Page 9: ...values from 0 255 and the corresponding output valus A graphically presentation of the table represents the output charateristics For transferring the table into the DMX LED Dimmer X9 HR a PC connection cable and a USB connection from the PC is necessary Please connect the cable and the PC one another and the CTRL connection from the DMX LED Dimmer X9 HR as shown in the right picture Now start the...

Page 10: ... 9 B4 Master 1 OUT 1 R1 OUT 1 fine OUT 2 G1 OUT 2 fine OUT 9 B4 OUT 9 fine OUT 3 B1 OUT 3 fine OUT 4 R2 OUT 4 fine Master 2 Master 2 System master dimmer for all channels The value for the master dimmer corresponds with the DMX channel 1 which is used as master dimmer for all 9 outputs The DMX starting address represents the DMX channel on which begins the DMX values for the outputs The DMX addres...

Page 11: ...or using in correlation with video recording e g in the TV studio This will be activated as follows In this mode a DMX channel 256 steps will be used for the brightness settings The master dimmer options are combinable In this mode is a fixed LookUp table used which can t be changed High Frequency Mode 2kHz High Frequency Mode 4kHz ...

Page 12: ...DMX LED Dimmer X9 HR 12 Equipment DIN rail housing 1050 LED Dimmer Configuration cable ...

Page 13: ...obability of a failure a redundant system structure is necessary Initiation risk For the installation of the board the board must be connected and adjusted to foreign components according to the device paperwork This work can only be done by qualified personnel which read the full device paperwork and understand it Operating risk The Change or the operation under special conditions of the installe...

Page 14: ...information contained in this manual was arranged with largest care and after best knowledge Nevertheless errors are to be excluded not completely For this reason I see myself compelled to point out that I can take over neither a warranty nor the legal responsibility or any adhesion for consequences which decrease go back to incorrect data This document does not contain assured characteristics The...

Reviews: