background image

P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd      Rev C          10-09     Page 2

FACTORY DEFAULTS

System Setup Password…………………………………………………………………...…………………111111   (6 digits)
Door Open Password...…………………………………………………………………………...……………1234     (4 digits)
Door Open Mode……………………………………………………………………………………………………....Read card 
Reading Card Data Format…………………………………………………………………………………..Low weight 24Bits
Patrol Password………………………………………………………………………………...…………….1234567  (7 digits)
Duress Password………………………………………………………………..…Door open password or PIN + 9 (5 digits)
Shunt Function………………………………………………………………………………..………………….……….Disabled
Anti-Duress Function………………………………………………………………………………………..…………...Disabled
Patrol function…………………………………………………………………………………………………………….Disabled
Force Entry Alarm…...…………………………………………………………………………………………...………Disabled
Door Prop Alarm Detection Time..……………………………………………..……………………....0 SEC (00 = Disabled)
Door Prop Alarm………………………...………………………………………………………………………….…….Disabled
Password Error over 5 times (keypad lockout for 1 min) OR 

PIN Error over 5 times (deletes the cardholder)…………………..…………………………………………....Disabled

Patrol Relay Active Time…………………………………………..………………………………………….……1 SEC (fixed)
Strike Relay Active Time….………………………………………………………….……………5 SEC (00 = LATCH mode)
Alarm Relay Active Time………………………………………….……………………….…...10 SEC (00 = non-stop alarm)
Anti-Duress/Shunt Active Time…………………………….……………………………………………………………...1 SEC
Door Sensor Configuration Detection…………………..…………………………………..………………….Normally Open

BASIC OPERATION

The E4KP has two programmable entry modes:

Mode 1 (Default) – Card Only
Mode 2 – Card (or Enter Card Number) & PIN

In Normal Standby Mode, the LED on the E4KP will be Solid Red.
When the Strike Relay is active, the LED will be Solid Green.

To Open the Door using an HID card or fob (in Mode 1)

,

Present a valid card or fob within a couple of inches of the reader 

{Solid Green LED}

To Open the Door using an HID card or fob (in Mode 2)

,

Present a valid card or fob within a couple of inches of the reader 

{Slow Flashing Red LED}

Enter the 4-digit PIN + # 

{Solid Green LED}

QUICKSTART PROGRAMMING INSTRUCTIONS

Before enrolling any cards, the default Door Open Password (

1234 + #

) may be used to activate the Strike Relay.  

Once a card is enrolled, the Door Open Password will no longer function.

The following commands will program a specified number of sequential HID cards, and will set the strike relay time to 
5 seconds.  You will need the first card in the sequence.  This is the card with the lowest card number (see below)

Command

LED Indicator

Press  #

{Alternating Red & Green LED}

Press 5 + #

{Fast alternating Red & Green LED}

Present the first card in the sequence

{Flashing Red}

Enter the total number of cards + #

{Fast alternating Red & Green LED}

Press # twice. 

{Solid Red LED – Normal Standby Mode}

Present any of the cards to the reader.

{Solid Green LED – Strike Relay Active}

HI

D

PR
O

XI

M

IT

Y

XXXXX  XXXXXXXX-1

5-DIGIT

CARD NUMBER

Summary of Contents for E4KP ENTRYCHECK

Page 1: ... user cards Cost effective solution for access control and personnel management Access mode selectable 1 Proximity card only 2 Proximity card PIN Master code for programming functions Main password function Security password function Forced entry alarm Door prop alarm Duress output User card can be registered deleted in single or batch mode with consecutive numbers Reader Lockout activated when th...

Page 2: ...d Red When the Strike Relay is active the LED will be Solid Green To Open the Door using an HID card or fob in Mode 1 Present a valid card or fob within a couple of inches of the reader Solid Green LED To Open the Door using an HID card or fob in Mode 2 Present a valid card or fob within a couple of inches of the reader Slow Flashing Red LED Enter the 4 digit PIN Solid Green LED QUICKSTART PROGRAM...

Page 3: ...ally be found on one side of the HID Card or Fob See Pg 2 If a card ever needs to be deleted you will need the card or the card number Adding a Single Card OR Card Number Enter Programming Mode Alternating Red Green LED Press 4 Fast alternating Red Green LED Present Card OR Enter the Card Number 0 65535 Flashing Red LED Key in a 4 digit PIN If you do not want to enter a PIN just Press Fast alterna...

Page 4: ...isable Press 810 Alternating Red Green LED Press to exit Programming Solid Red LED NOTE DIP SWITCH 1 on the E5RM control module must be ON Shunt cannot be used if Anti Duress is enabled Set Anti Duress Relay Time Default Anti Duress Disabled With the Anti Duress Relay Enabled the Auxiliary K3 Relay will activate when the Door Open Password See Factory Defaults OR a User s PIN Entry Mode 2 ONLY is ...

Page 5: ...n condensing Change Default Passwords Enter Programming Mode Alternating Red Green LED To change System Setup Password Default 111111 Press New 6 digit Password Alternating Red Green LED To change Door Open Password Default 1234 Press New 4 digit Password Alternating Red Green LED To change Patrol Password Default 1234567 Press New 7 digit Password Alternating Red Green LED Press to exit Programmi...

Page 6: ...ti Duress feature and or Patrol Function 4 J1 J2 J3 Connectors are included with the E5RM Power Supply Exit Button Door Switch are sold separately P INSTALLATION INST Access Controls INST E4KP INST E4KP vsd Rev C 10 09 Page 6 5 For DC voltage electric strikes and electric bolt locks install a Metal Oxide Varistor MOV as close to the coil as possible to prevent kickback voltage from damaging the re...

Reviews: