P:\INSTALLATION INST\Access Controls\INST-E4KP\INST-E4KP.vsd Rev C 10-09 Page 2
FACTORY DEFAULTS
System Setup Password…………………………………………………………………...…………………111111 (6 digits)
Door Open Password...…………………………………………………………………………...……………1234 (4 digits)
Door Open Mode……………………………………………………………………………………………………....Read card
Reading Card Data Format…………………………………………………………………………………..Low weight 24Bits
Patrol Password………………………………………………………………………………...…………….1234567 (7 digits)
Duress Password………………………………………………………………..…Door open password or PIN + 9 (5 digits)
Shunt Function………………………………………………………………………………..………………….……….Disabled
Anti-Duress Function………………………………………………………………………………………..…………...Disabled
Patrol function…………………………………………………………………………………………………………….Disabled
Force Entry Alarm…...…………………………………………………………………………………………...………Disabled
Door Prop Alarm Detection Time..……………………………………………..……………………....0 SEC (00 = Disabled)
Door Prop Alarm………………………...………………………………………………………………………….…….Disabled
Password Error over 5 times (keypad lockout for 1 min) OR
PIN Error over 5 times (deletes the cardholder)…………………..…………………………………………....Disabled
Patrol Relay Active Time…………………………………………..………………………………………….……1 SEC (fixed)
Strike Relay Active Time….………………………………………………………….……………5 SEC (00 = LATCH mode)
Alarm Relay Active Time………………………………………….……………………….…...10 SEC (00 = non-stop alarm)
Anti-Duress/Shunt Active Time…………………………….……………………………………………………………...1 SEC
Door Sensor Configuration Detection…………………..…………………………………..………………….Normally Open
BASIC OPERATION
The E4KP has two programmable entry modes:
Mode 1 (Default) – Card Only
Mode 2 – Card (or Enter Card Number) & PIN
In Normal Standby Mode, the LED on the E4KP will be Solid Red.
When the Strike Relay is active, the LED will be Solid Green.
To Open the Door using an HID card or fob (in Mode 1)
,
Present a valid card or fob within a couple of inches of the reader
{Solid Green LED}
To Open the Door using an HID card or fob (in Mode 2)
,
Present a valid card or fob within a couple of inches of the reader
{Slow Flashing Red LED}
Enter the 4-digit PIN + #
{Solid Green LED}
QUICKSTART PROGRAMMING INSTRUCTIONS
Before enrolling any cards, the default Door Open Password (
1234 + #
) may be used to activate the Strike Relay.
Once a card is enrolled, the Door Open Password will no longer function.
The following commands will program a specified number of sequential HID cards, and will set the strike relay time to
5 seconds. You will need the first card in the sequence. This is the card with the lowest card number (see below)
Command
LED Indicator
Press #
{Alternating Red & Green LED}
Press 5 + #
{Fast alternating Red & Green LED}
Present the first card in the sequence
{Flashing Red}
Enter the total number of cards + #
{Fast alternating Red & Green LED}
Press # twice.
{Solid Red LED – Normal Standby Mode}
Present any of the cards to the reader.
{Solid Green LED – Strike Relay Active}
HI
D
PR
O
XI
M
IT
Y
XXXXX XXXXXXXX-1
5-DIGIT
CARD NUMBER