CHAPTER 15:12-/10-/8-bit Analog to Digital Converter
362
S6J3200 Series Hardware Manual Document Number: 002-04852 Rev. *G
If there is no idle trigger type set for any of logical channels, after all conversion requests are processed
A/D Converter goes to idle (power-down) state and BUSY flag becomes "0" until next conversion
request appears and resumption time elapses.
In case that idle trigger type is set (ADC12Bn_CHCTRL0 to 63.TRGTYP[1:0] = "11"), there will be
always at least one conversion request active and after BUSY flag is set first time to "1", it will not
change.
[bit5:0] ACH[5:0] : Converted logical channel number
This bit field depends on ADC12Bn_CTRL.ACHMD field setting.
−
If ACHMD is equal to "0", ACH represents currently converted logical channel number.
−
If ACHMD is equal to "1", ACH represents the last logical channel number whose conversion has
finished. ACH is updated at the end of the A/D conversion only in the case the corresponding trigger
status (ADC12Bn_TRGST0 to 1.TRGST and ADC12Bn_CHSTAT0 to 63.TRGST bits) is still "1".
Summary of Contents for S6J3200 Series
Page 1041: ...CHAPTER 28 LCD Controller 1040 S6J3200 Series Hardware Manual Document Number 002 04852 Rev G...
Page 1044: ...CHAPTER 28 LCD Controller S6J3200 Series Hardware Manual Document Number 002 04852 Rev G 1043...
Page 1047: ...CHAPTER 28 LCD Controller 1046 S6J3200 Series Hardware Manual Document Number 002 04852 Rev G...
Page 1050: ...CHAPTER 28 LCD Controller S6J3200 Series Hardware Manual Document Number 002 04852 Rev G 1049...
Page 1084: ...CHAPTER 28 LCD Controller S6J3200 Series Hardware Manual Document Number 002 04852 Rev G 1083...
Page 1086: ...CHAPTER 28 LCD Controller S6J3200 Series Hardware Manual Document Number 002 04852 Rev G 1085...
Page 1088: ...CHAPTER 28 LCD Controller S6J3200 Series Hardware Manual Document Number 002 04852 Rev G 1087...