Table 3-327. Register Call Summary for Register PM_WKDEP_MPU (continued)
PRCM Register Manual
•
MPU_PRM Registers Register Summary
Table 3-328. PM_EVGENCTRL_MPU
Address Offset
0x0000 00D4
Physical Address
0x4830 69D4
Instance
MPU_PRM
Description
This register allows controlling the feature of the event generator.
Type
RW
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
RESERVED
ENABLE
ONLOADMODE
OFFLOADMODE
Bits
Field Name
Description
Type
Reset
31:5
RESERVED
Write 0s for future compatibility . Read returns 0
R
0x0000000
4:3
OFFLOADMODE
OFF load mode setting
RW
0x2
0x0: Load on update of
0x1: Reserved
0x2: Load on MPU standby signal assertion
0x3: Auto load
2:1
ONLOADMODE
ON load mode setting
RW
0x1
0x0: Load on update of
0x1: Load on MPU standby signal de-assertion
0x2: Reserved
0x3: Auto load
0
ENABLE
Event generator control
RW
0x0
0x0: Disable event generator
0x1: Enable event generator
Table 3-329. Register Call Summary for Register PM_EVGENCTRL_MPU