Public Version
PRCM Basic Programming Model
www.ti.com
In the PRCM module, three event generator registers allow configuration of the event generator module:
•
(event generator control register): Event-generator settings
•
(event generator on-time register): On-time duration setting
•
(event generator off-time register): Off-time duration setting
3.6.1.5
Output Signal Polarity Control Registers
3.6.1.5.1 CM_POLCTRL (CM Polarity Control Register)
The
register allows the setting of the polarity of sys_clkout2 when gated (disabled).
sys_clkout2 can be gated to a low level or a high level, depending on the software programming of this
register.
shows the normal behavior of sys_clkout2 when gated.
400
Power, Reset, and Clock Management
SWPU177N – December 2009 – Revised November 2010
Copyright © 2009–2010, Texas Instruments Incorporated