Device
DPLL
x4
Control
registers
Control
registers
PRCM
System control
module
Clock generation control
Spreading control
scm-034
Public Version
www.ti.com
SCM Functional Description
13.4.11.2 Integration
The DPLLs/domains of the devices that support the EMI reduction feature are:
•
DSS/DSI DPLL
•
CORE domain DPLL
•
PER domain DPLL
•
USBHOST DPLL
shows the integration of DPLL-D in the device.
Figure 13-19. DPLL-D Integration
The control of the DPLL is done by the PRCM module and the SCM:
•
The PRCM module controls the clocking generation of the DPLL. For more information, see
Power, Reset, and Clock Management.
•
The SCM contains all necessary bits that control the EMI reduction feature (SSC).