Public Version
www.ti.com
SCM Register Manual
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
RESERVED
RESERVED
OBSERVABILITYDISABLE
Bits
Field Name
Description
Type
Reset
31:6
RESERVED
Read returns reset value.
R
0x0
5
OBSERVABILITYDISABLE
Control the observability feature
R/OCO
0x0
0x0:
Observability can be configured through the
ObsMux bit field in the CONTROL_DEBOBS
register.
0x1:
Observability is disabled. If pads are
configured for the hardware debug, output is
tied low.
4:0
RESERVED
Read returns reset value.
R
0x0
Table 13-101. Register Call Summary for Register CONTROL_PROT_CTRL
SCM Functional Description
•
SCM Register Manual
•
:
Table 13-102. CONTROL_DEVCONF1
Address Offset
0x0000 0068
Physical Address
Instance
GENERAL
0x4800 22D8
Description
register description
Type
RW
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
RESERVED
RESERVED
TVACEN
RESERVED
RESERVED
RESERVED
RESERVED
MCBSP5_CLKS
MCBSP4_CLKS
MCBSP3_CLKS
TVOUTBYPASS
SENSDMAREQ6
SENSDMAREQ5
SENSDMAREQ4
SENSDMAREQ3
SENSDMAREQ2
MPUFORCEWRNP
MMCSDIO2ADPCLKISEL
CARKITHSUSB0DATA1AUTOEN
CARKITHSUSB0DATA0AUTOEN
Bits
Field Name
Description
Type
Reset
31:24
RESERVED
Read returns reset value.
R
0x00
23
SENSDMAREQ6
Set sensitivity on SYS.nDMAREQ6 input pin
RW
0
0 : Level sensitivity
1 : Edge sensitivity
2581