WorkCentre 5335 Family Service Documentation
124-337, 124-338
Status Indicator RAPs
Initial Issue
124-337 ESS RAM RAP
An error was detected in the ESS RAM.
Procedure
•
Turn the power OFF then ON. If the problem persists, perform the following procedure to
repair it.
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Reinstall or replace all the RAM DIMM.
•
Remove and re-install the System Memory (
PL 35.2
).
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB (
PL 35.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB and RAM
DIMM.)
124-338 Duplicate Font ROMs RAP
The system detected that a duplicate Font ROM is installed.
Initial Actions
Check that the correct ROM DIMM are installed.
Procedure
1.
Pull out and insert the Prt-Kit or the ROM DIMM. Replace it.