BUS Updated 12/2011
07/2011
2-862
WorkCentre 5335 Family Service Documentation
116-342, 116-343
Initial Issue
Status Indicator RAPs
116-342 SESAMi Manager Fail RAP
An internal shutdown occurred due to an error in processing SNMP (Simple Network Manage-
ment Protocol).
Initial Actions
Power Off/On
Procedure
Reload Software (
GP 16
).
116-343 Main PWB IC RAP
An error is detected in the IC in the ESS PWB.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB (
PL 35.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB)