![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_8843081112.webp)
BUS Updated 12/2011
07/2011
4-51
WorkCentre 5335 Family Service Documentation
REP 6.11
Repairs & Adjustments
Initial Issue
REP 6.11 Control Panel Assembly
Parts List on
PL 1.7
Removal
1.
Switch off the power and disconnect the power cord.
2.
Open the Platen Cover or DADF.
3.
Remove the screws that secure the Control Panel (
Figure 1
).
(1) Remove the screws (x2).
Figure 1 Control Panel Screws
4.
Remove the screws that secure the Control Panel (
Figure 2
).
(1) Remove the screws (x2).
Figure 2 Control Panel Screws
5.
Remove the Control Panel (
Figure 3
).
(1) Hold the Control Panel and slide it slowly to the front.
(2) Release the UI Cable from the hooks.
(3) Release the hook at the bottom of the Connector Housing and disconnect the
connector.
(4) Disconnect the connector of the USB Cable.
Figure 3 Control Panel Removal
6.
Turn the Control Panel upside down.
7.
Remove the Overlay Cover (
Figure 4
).
(1) Release the hooks (x3) of the Overlay Cover.
(2) Remove the Overlay Cover in the direction of the arrow.
Figure 4 Overlay Cover Removal
1. Remove the screws (x2)