BUS Updated 12/2011
07/2011
6-44
WorkCentre 5335 Family Service Documentation
GP 10, GP 11
Initial Issue
General Procedures & Information
Special Procedure
1.
Press and hold the 0 key for 5 seconds, then while still holding down the 0 key, press the
Start button. The CE- Type Passcode screen will appear.
2.
Enter 6789 and press Confirm.
3.
Press the Log In/Out button on the control panel. The Maintenance/Diagnostics screen
will appear.
4.
Scroll to and select Adjustment/Others.
5.
Scroll to and select Machine ID/Billing Data Settings.
6.
Record the serial number for a correct PWB then select a PWB with the correct data.
7.
Select Start.
8.
Enter the correct serial number in the Serial Number screen and then select Confirm.
Enter the correct serial number again and select Confirm again.
9.
Select Close and check that all three columns are the same.
10. If the serial numbers match select Close and exit Service Rep. mode.
If two or more serial numbers DO NOT match the machine label serial number, escalate
the service call to Field Engineering or the NTC.
GP 11 Foreign Device Interface Setup
Purpose
This procedure explains the process for installing and configuring the Foreign Device Interface
(FDI).
Procedure
1.
Perform internal dip switch setup for the Bear DCS6061 FDI:
a.
Remove the 3 Phillips screws on under side of the FDI.
b.
Remove top cover to gain access to the internal DIP switches.
c.
Set switches as shown in
Figure 1
.
Figure 1 FDI Switches
d.
Reassemble the FDI.
2.
Connect the FDI:
a.
Switch off the power.
b.
Connect the cable from
P/J351
on the ESS PWB Chassis (
Figure 2
) to
J1
on the
FDI.
DIP Switches:
3,4, 5, 7 ON
1, 2, 6, 8, 9, 10 OFF
P2
J1