![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_8843081160.webp)
BUS Updated 12/2011
07/2011
4-101
WorkCentre 5335 Family Service Documentation
REP 12.5, REP 12.6
Repairs & Adjustments
Initial Issue
Figure 2 Removing the Bracket
Replacement
1.
Reverse the removal procedure for replacement.
REP 12.6 Set Clamp Home Sensor
Parts List on
PL 22.4
Removal
1.
Switch off the power and disconnect the power cord.
2.
Remove the Integrated Office Finisher from the machine (
REP 12.1
).
3.
Remove the Rear Cover (
PL 22.1
)
4.
Disconnect the Connector (
Figure 1
):
(1)Release Clamp and remove the wire.
(2)Disconnect Connector.
Figure 1 Disconnecting Connector
5.
Remove the Set Clamp Home Sensor Assembly (
Figure 2
):
(1)Remove Screw.
(2)Remove Set Clamp Home Sensor Assembly.