BUS Updated 12/2011
07/2011
2-117
WorkCentre 5335 Family Service Documentation
012-260
Status Indicator RAPs
Initial Issue
012-260 Eject Clamp Home Sensor On Failure RAP (LX)
BSD-ON:
BSD 12.22 - Office Finisher LX Eject Control (1 of 2)
After the Eject Clamp started ascending, the Eject Clamp Home Sensor did not turn On within
500ms.
Initial Actions
•
Manually operate the Eject mechanism. Check for binding, a dirty sensor, or damage.
•
Check the actuator for the Eject Clamp Home Sensor b for damage
Procedure
Execute
Component Control
[012-250], Eject Clamp Home Sensor. Block and unblock the
Eject Clamp Home Sensor The display changes.
Y
N
Check the wire between
J8870
pin 2 on the Eject Clamp Home Sensor and
P/J8988
pin
8 on the Finisher PWB for an open or short circuit, or loose or damaged connectors. The
wire is OK.
Y
N
Repair/replace as required.
Measure the voltage between
P/J8988
, pins 9 and 7 on the Finisher PWB. The voltage
is approx. +5VDC.
Y
N
Replace the Finisher PWB (
PL 23.16
).
Measure the voltage between
P/J8988
pin 8 on the Finisher PWB and GND. Actuate the
Eject Clamp Home Sensor. The voltage changes.
Y
N
Replace the Eject Clamp Home Sensor (
PL 23.11
).
Replace the Finisher PWB (
PL 23.16
).
Alternately execute
Component Control
[012-052], Eject Clamp Up and [012-053], Eject Clamp
Down. The Eject Motor (
PL 22.9
) starts up.
Y
N
Check the wires between
P/J8878
pins 1~6 on the Eject Motor and
P/J8983
pins 5~8 on
the Finisher PWB for an open or short circuit, or loose or damaged connectors
BSD 12.22
- Office Finisher LX Eject Control (1 of 2)
. The wires are OK.
Y
N
Repair/replace as required.
Measure the resistance of the Eject Motor between each pin of
P/J8878
-1/3/4/6. The
resistance is approx. 2Ohm.
Y
N
Replace the Eject Motor (
PL 23.11
).
Replace the Finisher PWB (
PL 23.16
). If the problem remains, replace the Eject Motor
(
PL 23.11
)
Go to
BSD 12.22 - Office Finisher LX Eject Control (1 of 2)
. Check for an intermittent circuit
or intermittent mechanical problem. If the check is OK, replace the Finisher PWB (
PL 23.16
).
A
A