BUS Updated 12/2011
07/2011
2-146
WorkCentre 5335 Family Service Documentation
016-229, 016-230
Initial Issue
Status Indicator RAPs
016-229 SW Option Failure RAP
BSD-ON:
BSD 16.1 - ESS
SW Option Fail (FCW-UI Not Exist) The extension MEM PWB is not installed.
NOTE: Even thought this refers to the UIs that are not installed on the machine the actual UI is
the MCW UI this fault can be generated if the ESS does not detect the UI is installed. Therefore
check the connections from the UI to the ESS PWB.
Procedure
Disconnect and reconnect the UI Cable at the ESS PWB.
016-230 SW Option Failed - PS Image Log Kit (License
Required) RAP
The PS-ROM was installed in a machine where SW key: "Image Log Kit Enabled" and SW key:
"Image Log Kit for PS Disabled" are specified. When the "PS-ROM" is installed in the machine,
the image log function cannot operate unless the "Image Log Kit for PS" has been installed.
Procedure
•
Switch the Machine Power Off then On.
•
If the problem is still present, In UI Diagnostics (
Accessing UI Diagnostics
) ensure that the
SW Key for the PS Image Log Kit is entered and enabled. Contact the System Adminis-