Status Indicator RAPs
012-903 (Integrated Finisher) Paper Remains at Compiler
Exit Sensor RAP
BSD-ON:
BSD 12.3 - Integrated Finisher Transportation
•
At Power On, the Compiler Exit Sensor detected paper.
•
While the Main Motor was operating at initialization at Power On, the Compiler Exit Sen-
sor detected paper.
•
When the Cycle down operation at the end of a job was complete, the Compiler Exit Sen-
sor was On.
Initial Actions
•
Check the power supply voltage at the customer site for a drop.
•
Check the Compiler Exit Sensor is properly installed and free from foreign objects and
that the actuator is not binding.
•
Power Off/ON.
Procedure
Check for paper remaining on the Compiler Exit Sensor and how it is installed. The sensor is
properly installed with no paper left there.
Y
N
Remove the remaining paper and reinstall the sensor properly.
Enter
Component Control
[012-150]. Actuate the Compiler Exit Sensor. The display
changes.
Y
N
Check the connections of
P/J8709
and
P/J8728
.
P/J8709
and
P/J8728
are securely
connected.
Y
N
Connect
P/J8709
and
P/J8728
.
Check for an open or short circuit between
P/J8709
and
P/J8728
. The wires between
P/J8709
and
P/J8728
are OK.
Y
N
Repair the open or short circuit.
Measure the voltage between Finisher PWB
P/J8709
-3 (+) and GND (-). The voltage is
5VDC.
Y
N
Go to
Integrated Finisher Wirenets
and check the +5VDC circuit.
Measure the voltage between Finisher PWB
P/J8709
-2 (+) and GND (-). Actuate the
Compiler Exit Sensor. The voltage changes.
Y
N
Replace the Compiler Exit Sensor (
PL 22.5
).
Check the wires and connectors for an intermittent open or short circuit. If the problem
continues, replace the Finisher PWB (
PL 22.7
).
Check the wires and connectors for an intermittent open or short circuit. If the problem contin-
ues, replace the Finisher PWB (
PL 22.7
).
012-935 (Integrated Finisher) Paper Remains at Entrance
Sensor RAP
BSD-ON:
BSD 12.3 Integrated Finisher Transportation
•
At Power On the Finisher Entrance Sensor detected paper.
•
While the Main Motor was operating at initialization at Power On, the Finisher Entrance
Sensor detected paper.
•
When the Cycle down operation at the end of a job was complete, the Finisher Entrance
Sensor was On.
Initial Actions
•
Check the power supply voltage at the customer site for a drop.
•
Check the Finisher Entrance Sensor is properly installed and free from foreign objects
and that the actuator is not binding.
•
Power Off/ON.
Procedure
Check for paper remaining on the Finisher Entrance Sensor and how it is installed. The sen-
sor is properly installed and free from paper.
Y
N
Remove the remaining paper and reinstall the sensor properly.
Enter
Component Control
[012-140]. Move the Finisher Entrance Sensor actuator by hand or
with a piece of paper. The display changes.
Y
N
Check the connections of
P/J8709
and
P/J8729
.
P/J8709
and
P/J8729
are securely
connected.
Y
N
Connect
P/J8709
and
P/J8729
securely.
Check for an open or short circuit between
P/J8709
and
P/J8729
. The wire between
P/J8709
and
P/J8729
are OK.
Y
N
Repair the open or short circuit.
Measure the voltage between
P/J8709
-6 (+) on the Finisher PWB and GND (-). The
voltage is approx. +5VDC.
Y
N
Go to
Integrated Finisher Wirenets
and check the +5VDC circuit.
Measure the voltage between
P/J8709
-5 (+) on the Finisher PWB and GND (-). Actuate
the Finisher Entrance Sensor. The voltage changes.
Y
N
Replace the Finisher Entrance Sensor (
PL 22.5
).
Check the wires and connectors for an intermittent open or short circuit. If the problem
continues, replace the Finisher PWB (
PL 22.7
).
Check the wires and connectors for an intermittent open or short circuit. If the problem contin-
ues, replace the Finisher PWB (
PL 22.7
).