![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_884308951.webp)
BUS Updated 12/2011
07/2011
2-959
WorkCentre 5335 Family Service Documentation
124-314, 124-315
Status Indicator RAPs
Initial Issue
124-314 IOT Speed RAP
BSD-ON:
BSD 3.8 - Electronic Billing
The IOT is not running at the correct speed.
Procedure
Turn the power OFF then ON. If the problem persists, perform the following procedure to
repair it.
Reload software
GP 16
. Replace the MCU PWB (
PL 18.2
) and the ESS PWB (
PL 35.2
).
Go to
Machine ID/Billing Data
.
124-315 IOT Speed Mismatch RAP
BSD-ON:
BSD 3.8 - Electronic Billing
There is an IOT speed mismatch.
Procedure
Execute
NVM Read/Write
. Compare the values in the following NVM locations:
[700-600]
[700-601]
[700-602]
The 3 values match.
Y
N
Go to
Machine ID/Billing Data
.
Reload software
GP 16
. Replace the MCU PWB (
PL 18.2
) and the ESS PWB (
PL 35.2
).