![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_884308434.webp)
BUS Updated 12/2011
07/2011
2-425
WorkCentre 5335 Family Service Documentation
024-979, 024-979
Status Indicator RAPs
Initial Issue
024-979 Low Staples RAP (Integrated Finisher)
BSD-ON:
BSD 12.5 - Integrated Finisher Staple Control
Staples Near Empty or Staple-feed failure.
Initial Actions
Power Off/On
Procedure
Execute
Component Control
[012-242 Low Staple Sensor]. Install and remove the Staple Car-
tridge. The display changes.
Y
N
Check the Staple Cartridge for failure or foreign substances. There are no foreign sub-
stances and nothing has failed.
Y
N
Repair the failure and remove the foreign substances.
Check the wires between
P/J8731
and
P/J8701
for a loose connection, or an open or a
short circuit. The wires are OK.
Y
N
Repair as required.
Measure the voltage between the Finisher PWB
P/J8701
-5 (+) and GND (-). The volt-
age is approx. +5VDC.
Y
N
Replace the Finisher PWB (
PL 22.7
).
Measure the voltage between the Finisher PWB
P/J8701
-7 (+) and GND (-). Install and
remove the Staple Cartridge. The voltage changes.
Y
N
Replace the Finisher PWB (
PL 22.7
).
Replace the Staple Assembly (
PL 22.4
) If the problem persists, replace the Finisher PWB
(
PL 22.7
).
Check the sw version of the controller sw - update if required. Replace the Finisher PWB (
PL
22.7
) If the problem persists, replace the MCU PWB (
PL 18.2
).
024-979 Low Staples RAP (Finisher LX)
BSD-ON:
BSD 12.21 - Office Finisher LX Staple Control
Staples Near Empty or Staple-feed failure.
Initial Actions
Power Off/On
Procedure
Execute
Component Control
[012-242 Low Staple Sensor]. Install and remove the Staple Car-
tridge. The display changes.
Y
N
Check the Staple Cartridge for failure or foreign substances. There are no foreign sub-
stances and nothing has failed.
Y
N
Repair the failure and remove the foreign substances.
Check the wires between
J8886
and
P/J8981
for a loose connection, or an open or a
short circuit. The wires are OK.
Y
N
Repair as required.
Measure the voltage between the Finisher PWB
J8886
-5 (+) and GND (-). The voltage
is approx. +5VDC.
Y
N
Replace the Finisher PWB (
PL 22.7
).
Measure the voltage between the Finisher PWB
J8886
-7 (+) and GND (-). Install and
remove the Staple Cartridge. The voltage changes.
Y
N
Replace the Finisher PWB (
PL 23.16
).
Replace the Staple Assembly (
PL 23.4
) If the problem persists, replace the Finisher PWB
(
PL 23.16
).
Check the sw version of the controller sw - update if required. Replace the Finisher PWB (
PL
23.16
).