BUS Updated 12/2011
07/2011
2-997
WorkCentre 5335 Family Service Documentation
133-210 , 133-211
Status Indicator RAPs
Initial Issue
133-210 Illegal Fax Parameter RAP
BSD-ON:
BSD 34.1 - FAX
The parameter value is incorrect due to reasons such as excessive length.
The required parameter is not sent.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the PWB’s in the FAX Module)
•
Check the sw version of the fax & controller sw - update if required
•
Perform FAX Diagnostic
GP 13
•
Replace the Fax PWB (
PL 18.5
)
133-211 Fax Parameter Value Invalid RAP
BSD-ON:
BSD 34.1 - FAX
A parameter value exceeds the range or the required parameter is not sent.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the PWB’s in the FAX Module)
•
Check the sw version of the fax & controller sw - update if required
•
Perform FAX Diagnostic
GP 13
•
Replace the Fax PWB (
PL 18.5
)