BUS Updated 12/2011
07/2011
2-131
WorkCentre 5335 Family Service Documentation
012-923, 012-935
Status Indicator RAPs
Initial Issue
012-923 H-Transport Entrance Sensor Static Jam RAP (LX)
BSD-ON:
BSD 12.14 - Office Finisher LX Horizontal Transportation
During standby, paper was detected by the H-Transport Entrance Sensor.
Initial Actions
Check the paper path. If no paper is found continue with this RAP.
Clean the sensor.
Procedure
Execute
Component Control
[012-190], H-Transport Entrance Sensor. Actuate the H-Transport
Entrance Sensor (
PL 23.4
). The display changes.
Y
N
Check the wire between
J8861
pin 2 and
J8897
pin 6 for an open or short circuit, or a
loose or damaged connector. The wire is OK.
Y
N
Repair/reconnect as required.
Measure the voltage between
J8897
, pins 4 and 5 on the Finisher PWB (
BSD 12.14 -
Office Finisher LX Horizontal Transportation
). The voltage is approx. +5VDC.
Y
N
Replace the Finisher PWB (
PL 23.16
).
Measure the voltage between
J8897
, pin 6 on the Finisher PWB and GND (
BSD 12.14 -
Office Finisher LX Horizontal Transportation
). Actuate the H-Transport Entrance Sen-
sor. The voltage changes.
Y
N
Replace the H-Transport Entrance Sensor (
PL 23.4
).
Replace the Finisher PWB (
PL 23.16
).
If the problem continues, replace the Finisher PWB (
PL 23.16
).
012-935 Paper at Finisher Entrance Sensor RAP (LX)
BSD-ON:
BSD 12.16 - Office Finisher LX Transportation
Control logic reports paper at the Finisher Entrance Sensor.
Initial Actions
•
Check for obstructions in the paper path
•
Check that the Finisher is docked correctly to ensure proper Transport Gate operation
Procedure
Enter
Component Control
[012-100], Finisher Entrance Sensor. Select Start. Actuate the Fin-
isher Entrance Sensor. The display changes.
Y
N
Check the wire between
J8868
pin 2 and
P/J8988
pin 2 for an open or short circuit, or a
loose or damaged connector. The wire is OK.
Y
N
Repair/reconnect as required.
Measure the voltage between
P/J8988
pins 3 and 1 on the Finisher PWB (
BSD 12.16 -
Office Finisher LX Transportation
). The voltage is approx. +5VDC.
Y
N
Replace the Finisher PWB (
PL 23.16
).
Measure the voltage between
P/J8988
pin 2 on the Finisher PWB and GND (
BSD 12.16 -
Office Finisher LX Transportation
). Actuate the Finisher Entrance Sensor. The volt-
age changes.
Y
N
Replace the Finisher Entrance Sensor (
PL 23.14
).
Replace the Finisher PWB (
PL 23.16
).
Replace the Finisher PWB (
PL 23.16
).