![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_884308505.webp)
BUS Updated 12/2011
07/2011
2-498
WorkCentre 5335 Family Service Documentation
027-754, 027-760
Initial Issue
Status Indicator RAPs
027-754 Job Flow Service File Signature Mismatch RAP
Job flow service File signature setting mismatch.
Procedure
•
Check the system data setting of the XDW/PDF signature and the signature setting that is
specified in the instruction. If the system data setting is different from the setting in the
instruction, either change the instruction or change the system data
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required (
GP 6
,
GP 16
)
027-760 XJT Command Fail RAP
Job Fail. XJT Command Error (Parameter setting out of specifications). Incorrect Command
from XDOD Client.
Procedure
•
Check the following:
Check 1: Check if the parameter setting specified in XDOD client is out of system specifi-
cations.
Check 2: Check the XDOD client and Controller versions, and then save the XDOD job
ticket and contact Support G for checking.
(It would be the best if PRN file can be obtained, but it is not possible from the XDOD cli-
ent.)
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required (
GP 6
,
GP 16
)