![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_884308436.webp)
BUS Updated 12/2011
07/2011
2-427
WorkCentre 5335 Family Service Documentation
024-984, 024-989
Status Indicator RAPs
Initial Issue
024-984 Booklet Low Staple Front RAP
BSD-ON:
BSD 12.21 - Office Finisher LX Staple Control
The Booklet Low Staple Software detects low staple condition just before Booklet Staple Front
starts operating.
Procedure
•
Go to
012-291
(Office Finisher LX).
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required (
GP 16
)
024-989 Booklet Low Staple R RAP
BSD-ON:
BSD 12.27 - Office Finisher Booklet Staple Control (2 of 2 - Rear)
1.
Booklet Stapler Low Staple R signal ON was detected just before Stapling operation.
2.
Booklet Stapler Low Staple R signal was detected at Power ON, at initialization, or when
the interlock was closed.
Procedure
•
Check for Staple needles and reload them correctly.
If the problem persists, refer to the
BSD 12.27 - Office Finisher Booklet Staple Control (2
of 2 - Rear)
and check the Rear Low Staple Switch circuit for an open or short.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required (
GP 16
)