BUS Updated 12/2011
07/2011
2-973
WorkCentre 5335 Family Service Documentation
124-345, 124-346
Status Indicator RAPs
Initial Issue
124-345 Billing Meter Type Restoration Fail RAP
BSD-ON:
BSD 3.8 - Electronic Billing
System Fail. Billing Meter Type Fail (One mismatches the others but cannot be automatically
repaired.) When one billing meter type did not match, this machine tried to automatically cor-
rect it but failed.
Procedure
Power OFF then ON. If the problem persists, perform the following:
•
In
NVM Read/Write
compare the values in the following NVMs: 720-002 and 720-062. If
the values in both are the same, replace the MCU PWB (
PL 18.2
).
Reload software
GP 16
. If they are different, replace the ESS PWB.
124-346 All Billing Count Types Mismatch RAP
BSD-ON:
BSD 3.8 - Electronic Billing
System Fail. Billing Count Type Fail (All the three are different from each other.) All the billing
count types kept at multiple locations are different.
Procedure
Power OFF then ON. If the problem persists, perform the following:
Reload software
GP 16
. Replace the MCU PWB (
PL 18.2
) and the ESS PWB (
PL 35.2
).