BUS Updated 12/2011
07/2011
2-158
WorkCentre 5335 Family Service Documentation
016-331 Memory Diag Fail-2 RAP, 016-332 Memory
Initial Issue
Status Indicator RAPs
016-331 Memory Diag Fail-2 RAP
BSD-ON:
BSD 16.1 - ESS
Cont SystemMemory Diag Fail-2. Capacity of Slot2 loaded memory is out of spec.
Procedure
•
Power Off/On.
•
Check the sw version of the controller sw - update if required
•
Remove/insert ESS RAM DIMM.
•
Replace ESS RAM DIMM (
PL 35.2
).
•
Replace ESS PWB (
PL 35.2
).
016-332 Memory Diag Fail-3 RAP
BSD-ON:
BSD 16.1 - ESS
Cont SystemMemory Diag Fail-3. Capacity of Slot3 loaded memory is out of spec.
Procedure
•
Power Off/On.
•
Check the sw version of the controller sw - update if required
•
Remove/insert ESS RAM DIMM.
•
Replace ESS RAM DIMM (
PL 35.2
).
•
Replace ESS PWB (
PL 35.2
).