Status Indicator RAPs
005-275 DADF RAM Test Fail RAP
BSD-ON:
BSD 3.5 - ESS-DADF Communication
The DADF PWB RAM failed during the Read/Write operation. (At Power ON)
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
If the problem persists switch the power OFF then ON.
Check the sw version of the controller sw - update if required (
GP 16
). If no problems are
found, replace the DADF PWB (
PL 51.2
).
005-280 DADF EEPROM. Fail RAP
BSD-ON:
BSD 3.5 - ESS-DADF Communication
The DADF EEPROM. Read/Write operation failed.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
If the problem persists after turning the power OFF then ON. Check the sw version of the con-
troller sw - update if required. Replace the DADF PWB (
PL 51.2
).