BUS Updated 12/2011
07/2011
4-83
WorkCentre 5335 Family Service Documentation
REP 10.2
Repairs & Adjustments
Initial Issue
4.
Remove the Left Hand Cover (7 Screws) (
Figure 3
).
NOTE: The Left Hand Cover Screws have a different thread than the other screws, keep
them with the cover for re-installation.
Figure 3 Removing Screws
5.
Remove the Harness Guide (
Figure 4
).
a.
Loosen the top screw, remove the bottom screw.
Figure 4 Removing Screws
6.
Remove the Duplex Assembly from the Left Hand Cover (4 Screws) (
Figure 5
).
Figure 5 Removing Screws
7.
Remove the Duplex Sensor (
Figure 6
).
NOTE: Be careful not to damage or lose the Sensor Actuator Spring.
Figure 6 Duplex Sensor
Replacement
1.
To install, carry out the removal steps in reverse order.
4
5
6