![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_884308055.webp)
BUS Updated 12/2011
07/2011
2-39
WorkCentre 5335 Family Service Documentation
003-751, 003-752
Status Indicator RAPs
Initial Issue
003-751 Panther Capacity RAP
The Panther (continuous data protection protocol or utility) - Image data too small for IOT Hard-
ware to handle found in document range designation and scan area range (Width mm X
Length mm).
Procedure
•
Increase resolution. To increase Scan size range (Width mm X Length mm).
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - reload Software (
GP 16
)
003-752 600dpi Cannot be Scanned RAP
BSD-ON:
BSD 3.5 - ESS-DADF Communication
This status code is displayed - Unscannable 600dpi resolution detected after DADF Mix Duplex
Mode Job is accepted.
Procedure
Perform scanning below 400 dpi resolution or perform scanning in other than mixed
mode.
If powering OFF then ON does not resolve the problem, perform the following:
1.
Check the connection between IIT PWB and ESS PWB.
2.
Check the sw version of the controller sw - reload Software (
GP 16
)
3.
Replace IIT PWB (Switch the EEPROM) (
PL 1.6
)
4.
Replace ESS PWB (
PL 35.2
).