![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_884308803.webp)
BUS Updated 12/2011
07/2011
2-804
WorkCentre 5335 Family Service Documentation
077-106, 077-109
Initial Issue
Status Indicator RAPs
077-106 Exit Sensor 1 On Jam RAP
BSD-ON:
BSD 4.1 - Main Drive Control
BSD-ON:
BSD 10.2 - Fusing
The Fuser Exit Sensor does not turn ON within the specified time after the Registration Clutch
On.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
The Fuser Exit Sensor for failure:
Component Control
[077-101] (
PL 7.1
)
•
A paper transportation failure due to a foreign substance/burr on the paper path
•
The Fuser Exit Sensor for contamination, improper installation, and Actuator operation
failure
•
Each Takeaway Roll and Pinch Roll for contamination, wear, and revolution failure
•
The Registration Roll and Pinch Roll for contamination, wear, and revolution failure
•
The BTR for contamination, wear, and revolution failure
•
The Fuser for wound up, stuck paper
•
The Fuser Drive Gear for wear and damage
•
Use of paper out of spec
Reload the machine software (
GP 16
). If no problems are found, replace the MCU PWB (
PL
18.2
).
077-109 Exit Sensor 2 On Jam RAP
BSD-ON:
BSD 10.3 - Exit Transportation
BSD-ON:
BSD 10.4 - Exit 2 Drive
After the Fuser Exit Sensor turned ON, the Exit 2 Sensor did not turn ON within the specified
time.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Initial Actions
Check the following:
•
A paper transportation failure due to a foreign substance/burr on the paper path
•
Each Exit Roll and Pinch Roll for contamination, wear, and revolution failure
•
The Fuser for wound up, stuck paper
•
Each Exit Roll Drive Gear for wear and damage
•
The Exit 1 Gate for operation failure
•
Use of paper out of spec
•
The Exit 2 Sensor for contamination, improper installation, and Actuator operation failure
Procedure
Check the following:
•
The Exit 2 Sensor for failure:
Component Control
[077-100] (
PL 17.4
)
•
The connection between the Exit 2 Sensor
P/J115
and the MCU PWB
P/J411
for open
circuit, short circuit, and poor contact
•
The Exit 2 Motor for revolution failure:
Component Control
[077-015] (
PL 17.5
)
•
The Exit Gate Solenoid for failure:
Component Control
[077-004] (
PL 17.4
)
Reload the machine software (
GP 16
). If no problems are found, replace the MCU PWB (
PL
18.2
).