016-351, 016-360
Status Indicator RAPs
Initial Issue
016-351 ESS EEPROM DIAG Failure 2 RAP
BSD-ON:
BSD 16.1 - ESS
Read/Write/Verify error for the ESS EEPROM.
Initial Actions
Power Off/On.
Procedure
1.
Check connections between the following components:
•
ESS EEPROM and ESS PWB (check for bent pins etc.) (
PL 35.2
).
2.
Check the sw version of the controller sw - update if required
3.
If problem persists replace ESS PWB.
PL 35.3
.
016-360 Cont UI Fail-1 RAP
BSD-ON:
BSD 16.1 - ESS
Cont UI Diagnostic Fail-1. An error occurred during W/R/V test of PCI Config interval.
Procedure
Turn the power OFF then ON. If the problem persists, perform the following:
1.
Remove and re-install the UI I/F PWB (
PL 1.7
).
2.
Check the sw version of the controller sw - update if required
3.
If problem persists replace ESS PWB.
PL 35.3
.
4.
Replace the UI I/F PWB (
PL 1.7
).
5.
Replace the ESS PWB (
PL 35.2
).