Status Indicator RAPs
005-146 DADF Pre Registration Sensor Off Jam RAP
BSD-ON:
BSD 5.5 - Document Feed (2 of 2)
BSD-ON:
BSD 5.6 - Document Scan and Invert
After the DADF Feed Out Sensor turned OFF in 1 Sided mode, the DADF Pre Registration
Sensor did not turn OFF within the specified time.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
Transportation failure due to foreign substance in the document path
•
The surface of the roll for foreign substance
•
The surface of the roll for wear
•
Check the sw version of the controller sw - update if required.
•
DADF Registration Motor:
Component Control
[005-033] (
PL 51.5
)
•
DADF Feed Motor:
Component Control
[005-010] (
PL 51.5
)
•
Check if the Exit Roll is nipping properly. (Including the operations of Exit Nip Release
Solenoid (
Component Control
[005-072])) (
PL 51.6
)
•
Check the circuit between the DADF Pre Registration Sensor and the DADF PWB
•
DADF Pre Registration Sensor:
Component Control
[005-206] (
PL 51.17
)
•
DADF PWB failure. (
PL 51.2
)
005-147 DADF Pre Registration Sensor Off Jam (Invert)
RAP
BSD-ON:
BSD 5.5 - Document Feed (2 of 2)
BSD-ON:
BSD 5.6 - Document Scan and Invert
After the DADF Registration Motor turned ON at Invert, the DADF Pre Registration Sensor did
not turn OFF within the specified time.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
Transportation failure due to foreign substance in the document path
•
The surface of the roll for foreign substance
•
The surface of the roll for wear
•
Check the sw version of the controller sw - update if required.
•
DADF Registration Motor:
Component Control
[005-033] (
PL 51.5
)
•
DADF Feed Motor:
Component Control
[005-010] (
PL 51.5
)
•
Check the circuit between the DADF Pre Registration Sensor and the DADF PWB
•
DADF Pre Registration Sensor:
Component Control
[005-206] (
PL 51.17
)
•
DADF PWB failure. (
PL 51.2
)