Initial Issue
024-939 OHP Kind Mismatch (Not white frame OHP) RAP
BSD-ON:
BSD 7.5 - Tray 1 Paper Stacking
Operation Error. Paper Type Mismatch. The system is shut down (stop) if Transparencies with
borders are detected regardless of the paper type setting in the Controller.
Transparencies are loaded when a non-transparencies job is performed.
Other paper is loaded when a Transparencies job is performed
Transparencies with borders was detected.
Jam occurs when borders were detected by checking transparencies for borders (by the
OHP Sensor) after feeding started.
Procedure
•
Check UI Settings and ensure that Tray 5 is selected with the correct media.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required (
GP 16
)
024-942 Booklet Sheet Over Count RAP
Booklet Sheets Over Count. The number of sheets in a booklet is over the limit.
Initial Actions
Check the maximum number of sheets for Booklet.
Procedure
Program job in compliance with the maximum number of sheets for Booklet. Switch the power
OFF then ON.Cancel Booklet. The same error recurs.
Y
N
Bind sheets by the maximum number of sheets for Booklet.
Replace the Booklet PWB (
PL 23.21
) followed by the Finisher PWB (
PL 22.7
) or (
PL 23.16
)
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required (
GP 16
)