BUS Updated 12/2011
07/2011
2-881
WorkCentre 5335 Family Service Documentation
116-384 , 116-385
Status Indicator RAPs
Initial Issue
116-384 DCS Fatal Error RAP
DCS-related fatal error.
Due to an error in software processing, subsequent processes cannot be performed.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Reinstall or replace the DIMM (
PL 35.2
).
•
Remove and re-install or replace the System Memory and Page Memory DIMMs (
PL
35.2
).
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB (
PL 35.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB)
116-385 IDC Software RAP
An internal shutdown occurred after an IDC (scripting language) processing error.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Reinstall or replace the DIMM (
PL 35.2
).
•
Remove and re-install or replace the System Memory and Page Memory DIMMs (
PL
35.2
).
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB (
PL 35.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB)