BUS Updated 12/2011
07/2011
2-154
WorkCentre 5335 Family Service Documentation
016-320, 016-321
Initial Issue
Status Indicator RAPs
016-320 Doc Conversion SW Error RAP
BSD-ON:
BSD 16.1 - ESS
A fatal error with doc conversion software was detected.
Procedure
If powering OFF then ON does not resolve the problem, perform the following:
1.
Check ESS PWB and IIT PWB connections
2.
If the above actions do not resolve the problem, replace ESS PWB (
PL 35.2
).
3.
Reinstall the software.
016-321 Fax Module RAP
BSD-ON:
BSD 34.1 - FAX
With SysCheckFax(), ERROR is returned. If PFNOTEXIST is returned, M/C configuration is
regarded as that without FAX.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Perform FAX Diagnostic
GP 13
•
Disconnect then reconnect the PWBs in the FAX Module)
•
Check the sw version of the fax & controller sw - update if required
•
Replace the Fax PWB (
PL 18.5
)