BUS Updated 12/2011
07/2011
4-39
WorkCentre 5335 Family Service Documentation
REP 6.3, REP 6.4
Repairs & Adjustments
Initial Issue
REP 6.3 Platen Glass
Parts List on
PL 1.2
Removal
1.
Switch off the power and disconnect the power cord.
2.
Open the Platen Cover or DADF.
3.
Remove the Platen Glass (
Figure 1
)
(1) Remove the screws (x2).
(2) Remove the Right Side Plate.
(3) Remove the Platen Glass.
Figure 1 Platen Glass Removal
Replacement
1.
To install, carry out the removal steps in reverse order taking note of the following:
NOTE: Push the Platen Glass in the direction of arrow A and the Right Side Plate in the direc-
tion of arrow B (
Figure 2
)
Figure 2 Platen Glass Positioning
REP 6.4 CCD Lens Assembly
Parts List on
PL 1.2
Removal
NOTE: Light axis correction using UI Diagnostics is required after replacing the parts. After
replacement, always check the light axis and perform the light axis correction adjustment
where necessary (The correction steps are described in this procedure.)
1.
Switch off the power and disconnect the power cord.
2.
Remove the following parts:
•
Platen Glass (
REP 6.3
)
•
Lens Cover (
PL 1.2
)
3.
Move the APS Sensor (
Figure 1
)
(1) Remove the screw.
(2) Release the harness from the clamps (x3).
(3) Move the APS Sensor.
Figure 1 APS Sensor
4.
Disconnect the CCD Flexible Print Cable (
Figure 2
)
(1) Release the hook and disconnect the connector.