Status Indicator RAPs
003-753 300dpi Cannot be Scanned RAP
BSD-ON:
BSD 3.5 - ESS-DADF Communication
This status code is displayed if - Unscannable 300dpi or higher resolution detected after DADF
Mix Duplex Mode Job is accepted.
Procedure
•
Perform scanning below 200 dpi resolution.
Or perform scanning in other than mixed mode.
•
If powering OFF then ON does not resolve the problem, perform the following:
1.
Check the connection between IIT PWB and ESS PWB.
2.
Check the sw version of the controller sw - reload Software (
GP 16
)
3.
Replace IIT PWB (Switch the EEPROM) (
PL 1.6
)
4.
Replace ESS PWB (
PL 35.2
).
003-754 Scan Recoverable Error RAP
BSD-ON:
BSD 3.5 - ESS-DADF Communication
Recoverable high-compression Scan error
Procedure
•
Retry the job.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - reload Software (