BUS Updated 12/2011
07/2011
4-181
WorkCentre 5335 Family Service Documentation
REP 19.4
Repairs & Adjustments
Initial Issue
Removing the HCF Front Tray Cables
1.
Remove the (5) screws securing the HCF Tray’s Front Cover.
2.
At the front of the HCF Tray, begin to free up movement of the front Tray Cable Pulley
(
Figure 7
).
a.
Remove the E-Ring on the Lift Shaft.
b.
Slide the bearing to the rear on the Lift Shaft.
c.
Front Tray Cable Pulley
Figure 7 Lift Shaft Front Tray Cable Pulley
NOTE: You will not be able to release the cable ends from underneath the Tray Cable Pulley
until you perform the next step, which puts slack in the cable enabling the Lift Shaft to be disen-
gaged from its bracket, and the Tray Cable Pulley moved farther to the right releasing the cable
ends.
3.
Remove the E-Rings, Wire Guides, and Pulleys from the front of the HCF Tray (
Figure 8
).
Figure 8 Preparing to remove the Front Tray Cables
4.
When both sections of the cable are slack, disengage the Lift Shaft from the frame and
slide the Tray Cable Pulley to the front of the Lift Shaft to release the Rear Lift Cable ends
that are trapped in the pocket underneath the Tray Cable Pulley (
Figure 9
).
Figure 9 Releasing the Cable ends from the Lift Shaft
1
Remove E-Rings (2), Wire
Guides (2), and Pulleys (2)