![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_8843081202.webp)
BUS Updated 12/2011
07/2011
4-144
WorkCentre 5335 Family Service Documentation
REP 13.9
Initial Issue
Repairs & Adjustments
Replacement
1.
Align the Eject Cover with the Pins (2) on both sides, and slide it to the right (
Figure 2
).
NOTE: The left side of the Cover is now captured by the Pins and cannot be lifted up.
Figure 2 Aligning the Eject Cover
2.
Position the Eject Cover so that the Latch is inserted in the hole (
Figure 3
).
NOTE: The Latch must be outside the hole.
Figure 3 Inserting the Latch through the hole in the Cover
3.
Place the Latch Spring in the position shown (
Figure 4
).
Figure 4 Positioning the Latch Spring
Pin (2)
Eject Cover
Latch
Eject Cover
Latch Spring