BUS Updated 12/2011
07/2011
2-1009
WorkCentre 5335 Family Service Documentation
134-210, 134-211
Status Indicator RAPs
Initial Issue
134-210 Fax Controller Parameter RAP
BSD-ON:
BSD 34.1 - FAX
The parameter value is incorrect or the required parameter is not sent.
Initial Actions
Power Off/On
Procedure
Pull out and insert the Fax PWB (
PL 18.5
). The problem persists.
Y
N
Return to Service Call Procedures.
Check the electrical connections on the Fax PWB (
PL 18.5
). The connectors are securely
connected.
Y
N
Connect the connectors.
Switch on the power. The problem persists.
Y
N
Return to Service Call Procedures.
Reload software
GP 16
. Replace the Fax PWB (
PL 18.5
).
134-211 FAX PWB RAP
BSD-ON:
BSD 34.1 - FAX
A failure is detected on the Fax PWB.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the PWBs in the FAX Module)
•
Check the sw version of the fax & controller sw - update if required
•
Perform FAX Diagnostic
GP 13
•
Replace the Fax PWB (
PL 18.5
)