BUS Updated 12/2011
07/2011
2-813
WorkCentre 5335 Family Service Documentation
077-902, 077-907
Status Indicator RAPs
Initial Issue
077-902 Exit Sensor 2 Static Jam RAP
BSD-ON:
BSD 10.3 - Exit Transportation
When the power was turned ON, the M/C was stopped (Cycle Down/ Shut Down), or when the
interlocks were closed (all interlocks including options), the Exit 2 Sensor detected paper.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
The Exit 2 Sensor for remaining paper, contamination, Actuator return failure, or improper
installation
•
The Exit 2 Sensor for failure:
Component Control
[077-100] (
PL 17.4
)
•
The connection between the Exit 2 Sensor
P/J115
and the MCU PWB
P/J411
for open
circuit, short circuit, and poor contact
•
The L/H Upper Cover Assembly for damage or mismatch
Reload the machine software (
GP 16
). If no problems are found, replace the MCU PWB (
PL
18.2
).
077-907 Duplex Sensor Static Jam RAP
BSD-ON:
BSD 10. 5 - Duplex
When the power was turned ON, the M/C was stopped (Cycle Down/ Shut Down), or when the
interlocks were closed (all interlocks including options), the Duplex Sensor detected paper.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
The Duplex Sensor for remaining paper, contamination, Actuator return failure, or
improper installation
•
The Duplex Sensor for failure:
Component Control
[077-105] (
PL 14.4
)
•
The connection between the Duplex Sensor
P/J109
and the MCU PWB
P/J409
for open
circuit, short circuit, and poor contact
Reload the machine software (
GP 16
). If no problems are found, replace the MCU PWB (
PL
18.2
).