![background image](http://html.mh-extra.com/html/xerox/workcentre-5335-series/workcentre-5335-series_service-manual_884308916.webp)
BUS Updated 12/2011
07/2011
2-924
WorkCentre 5335 Family Service Documentation
121-350, 121-370
Initial Issue
Status Indicator RAPs
121-350 FDI Logic Fail RAP
BSD-ON:
BSD 3.7 - ESS-FDI Communication
System Fail. FDI - Unexpected Error. Due to an error in software processing, subsequent pro-
cesses cannot be performed.
Procedure
•
Checks whether they are installed correctly against the specifications.
If they are installed correctly, turn the power OFF then ON. If the problem persists, per-
form the following procedure to repair it.
•
Check the sw version of the controller sw - update if required
•
Reinstall or replace the FDI.
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Replace RAM DIMM on ESS PWB (
PL 35.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB and RAM
DIMM)
121-370 FDI Unexpected Error RAP
BSD-ON:
BSD 3.7 - ESS-FDI Communication
BSD-ON:
BSD 34.1 - FAX
System Fail. Unexpected Error.
Pflite Function Error
Library Function Error
Undefined Message/Undefined Parameter Received, etc.
Procedure
•
Checks whether they are installed correctly against the specifications.
If they are installed correctly, turn the power OFF then ON. If the problem persists, per-
form the following procedure to repair it.
•
Check the sw version of the controller sw - update if required
•
Reinstall or replace the FDI.
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Replace RAM DIMM on ESS PWB (
PL 35.2
)
•
Replace ESS PWB (
PL 35.2
) (If not fixed by this, reinstall the original ESS PWB and RAM
DIMM)